Fluke 289 TrendCapture TRMS Industrial Logging Multimeter (Fluke-289)
$699.00
True-RMS thermal multimeter, built-in IR camera, iFlex probe to 2500 A AC, wireless Fluke Connect, CAT III 1000 V / CAT IV 600 V Model Fluke 279 FC Product Type True-rms Thermal Multimeter Thermal Imager Built-in infrared camera, 102 × 77 resolution Infrared…
$1,100.00
Ask an engineer about this modelAdd several items, then request a quote at checkout.
True-RMS thermal multimeter, built-in IR camera, iFlex probe to 2500 A AC, wireless Fluke Connect, CAT III 1000 V / CAT IV 600 V.
| Product Type | True-rms Thermal Multimeter |
|---|---|
| Thermal Imager | Built-in infrared camera, 102 × 77 resolution |
| Infrared Temperature Range | 10 °C to 200 °C (14 °F to 392 °F) |
| Thermal Sensitivity (NETD) | ≤ 200 mK |
| Field of View | 36° (w) × 27° (h) |
| Distance to Spot | 162:1 |
| Display | 3.5 in (8.9 cm) color LCD; 6000 counts volts, amps, ohms; 10000 counts frequency; 1000 counts capacitance |
| Measurement Functions | 15 functions: AC voltage with low-pass filter, DC voltage, resistance, continuity, capacitance, diode test, min/max/avg, AC current (with iFlex), frequency |
| AC Voltage Range | 600.0 mV to 1000 V |
| DC Voltage Range | 600.0 mV to 1000 V |
| Resistance Range | 600.0 Ω to 50.00 MΩ |
| Capacitance Range | 1000 nF to 9999 µF |
| AC Current Range | 999.9 A; up to 2500 A AC with iFlex flexible current probe |
| Frequency Range | 99.99 Hz and 999.9 Hz |
| True RMS | Yes |
| Safety Rating | CAT III 1000 V, CAT IV 600 V |
| Maximum Voltage to Earth | 1000 V between any terminal and earth ground |
| Power | Fluke BP500 lithium ion battery |
| Battery Life | 10 hours minimum |
| RF Communications | 2.4 GHz ISM band; up to 20 m open air, up to 6.5 m through sheetrock wall, up to 3.5 m through concrete wall or steel electrical enclosure |
| Operating Temperature | 10 °C to 50 °C (14 °F to 122 °F) |
| Storage Temperature | 20 °C to 60 °C (-4 °F to 140 °F) |
| Relative Humidity | 0% to 90% (0 °C to 35 °C); 0% to 75% (35 °C to 40 °C); 0% to 45% (40 °C to 50 °C) |
| Operating Altitude | 2000 m |
|---|---|
| Storage Altitude | 12000 m |
| Size (H × W × L) | 5.7 cm × 9.4 cm × 21.6 cm (2.3 in × 3.7 in × 8.5 in) |
| Weight | 0.80 kg (1.75 lb) |
| Certifications | CSA, FCC, CE |
| AC mV | Range 600.0 mV; Resolution 0.1 mV; Accuracy 45 Hz to 500 Hz: ±(1.0% + 3) |
| DC Voltage | Ranges 6.000 V, 60.00 V, 600.0 V, 1000 V; Resolution 0.001 V to 1 V; Accuracy 6 V to 600 V: ±(0.09% + 2); 1000 V: ±(0.15% + 2) |
| DC mV | Range 600.0 mV; Resolution 0.1 mV; Accuracy ±(0.09% + 2) |
| Continuity | Range 600 Ω; Resolution 1 Ω; Beeper on at < 25 Ω; detects opens or shorts of 600 µs or longer |
| Diode Test | Range 2.000 V; Resolution 0.001 V; Accuracy ±(1% + 2) |
| Capacitance | Ranges 1000 nF, 10.00 µF, 100.0 µF, 9999 µF; Resolution 1 nF to 1 µF; Accuracy 1000 nF to 100 µF: ±(1.2% + 2); 9999 µF: ±10% typical |
| AC Current (with iFlex) | Ranges 999.9 A, 2500 A; Resolution 0.1 A and 1 A; Accuracy 45 Hz to 500 Hz: ±(3.0% + 5) |
| Frequency | Ranges 99.99 Hz and 999.9 Hz; Resolution 0.01 Hz and 0.1 Hz; Accuracy ±(0.1% + 1) |
| Continuity / Diode Input | Open circuit test voltage < 2.7 V DC; full scale voltage 2.000 V DC; typical short circuit current < 1.1 mA |
| MIN/MAX Recording | AC functions: captures changes > 900 ms, 40 counts; DC functions: captures changes > 350 ms, 12 counts |
| Infrared Camera Optics | Resolution 102 × 77; image capture frequency 8 Hz; detector type uncooled vanadium oxide; infrared spectral band 7.5 µm to 14 µm |
| Image Capture / Storage | Image review before save; internal memory stores up to 100 images; image transfer via Fluke Connect or SmartView software; file format .is2 |
| Display Update Rate | 4 readings per second |
| Temperature Coefficient | 0.1 × specified accuracy per °C for temperatures below 18 °C or above 28 °C |
| Safety / Compliance | Maximum voltage between any terminal and earth ground 1000 V; measurement category CAT III 1000 V, CAT IV 600 V; certifications CSA, FCC, CE |
| Optional Current Probes | Fluke i2500-10 iFlex Flexible Current Probe |
| Optional Power | Fluke BC500 AC Power Charger; Fluke BP500 Lithium Ion Battery 3000 mAh |
| Optional Cases | Fluke C280 Carrying Case |
True-RMS thermal multimeter, built-in IR camera, iFlex probe to 2500 A AC, wireless Fluke Connect, CAT III 1000 V / CAT IV 600 V.
The Fluke 279 FC iFlex True-RMS Thermal Multimeter combines a full digital multimeter with a built-in thermal imager so technicians can find, verify, and document electrical problems faster and safer. Scan for hot spots with the 102 × 77 IR camera, capture load measurements up to 2500 A AC using the included iFlex probe, and send results wirelessly through Fluke Connect to reduce time in front of live panels and improve troubleshooting efficiency.
Equip your team with the FLUKE-279-FC-iFlex to capture both thermal images and precise electrical measurements in a single trip and order today .
Have questions about IT equipment or need a quote? Our team responds within one business day.