The Juniper EX4650 Ethernet Switch delivers 2 Tb/s of Layer 2 and Layer 3 connectivity to networked devices such as secure routers, servers, and other switches. With 48 wire-speed 25 GbE small form-factor pluggable and pluggable plus transceiver (SFP/SFP+/SFP28) ports and 8 wire-speed 100 GbE quad SFP+ transceiver (QSFP+/QSP28) ports in a compact 1U platform, this device provides the flexibility to support mixed 1 GbE, 25 GbE and 100 GbE environments. It comes with two power cords, a 4-post rack mount kit and front-to-back airflow.
| Product Family | EX4650 Series |
|---|---|
| Product Type | Ethernet Switch |
| Dimensions (HxWxD) Inches | 1.72 x 17.36 x 20.48 in (4.37 x 44.09 x 52.02 cm) Back-to-front (airflow in) for cold aisle deployment Management and console port connections |
| Weight | 23.7 lb (10.75 kg) |
| 1GbE SFP | 48 (24 copper 1GbE) |
| 10GbE SFP+ | 48/80 (with breakout cable) |
| 25GbE SFP28 | 48/80 (with breakout cable) |
| 40GbE QSFP+ | 8 (Each QSFP+ port can be configured as a 4 x 10GbE interface or as a 40 Gbps port) |
| 100GbE QSFP28 | 8 (Each QSFP28 port can be configured as a 4 x 25GbE interface or as a 100 Gbps port) |
| Power Consumption | Max load 450 W; typical load 260 W; idle load 160 W |
| Airflow | Redundant (N+1) and hot-pluggable fan modules for front-to-back and back-to-front airflow Redundant variable-speed fans to reduce power draw |
| Switching capacity | 2 Tbps (unidirectional)/4 Tbps (bidirectional) |
| Layer 2/Layer 3 throughput (maximum with 64 byte packets) | 2976 Mpps (wire speed) |
| Switching mode | Cut-through and store-and-forward |
| Rack Installation Kit | Versatile four post mounting options for 19-in server rack or datacom rack |
| MAC addresses per system | 288,000 |
| VLAN Ids | 4093 |
| Number of ports per LAG | 64 |
| Number of link aggregation groups (LAGs) | 80 |
| Multiple Spanning Tree Protocol (MSTP) instances | 64 |
| VLAN Spanning Tree Protocol (VSTP) instances | 509 |
| Firewall filters | Ingress filters: 1500 Egress filters: 512 |
| IPv4 unicast prefixes | 360,000 |
| IPv4 unicast routes | 208,000 |
| IPv4 multicast routes | 104,000 |
| ECMP paths | 64 |
| IPv6 unicast prefixes | 170,000 |
| IPv6 unicast routes | 104,000 |
| IPv6 multicast routes | 52,000 |
| ARP entries | 64,000 |
| Traffic mirroring | Mirroring destination ports per switch: 4 Maximum number of mirroring sessions: 4 Mirroring destination VLANs per switch: 4 |
| Jumbo frame | 9,216 bytes |
| High Availability | Bidirectional Forwarding Detection (BFD) Uplink failure detection Dynamic Load Balancing |
| Data Center Bridging (DCB) | Priority-based flow control (PFC)—IEEE 802.1Qbb Data Center Bridging Capability Exchange (DCBX), DCBx FCoE, and iSCSI type, length, and value (TLVs) |
| Management and Analytics Platforms | Juniper Mist Wired Assurance for Campus Junos Space®Network Director for Campus Junos Space® Management |
| Server Virtualization Management and SDN-Related Protocols | VXLAN OVSDB EVPN-VXLAN |
| Traffic Mirroring | Port-based LAG port VLAN-based Filter-based Mirror to local Mirror to remote destinations (L2 over VLAN) |
| Operating temperature | 32° to 104° F (0° to 40° C) |
| Storage temperature | 40° to 158° F (-40° to 70° C) |
| Operating altitude | Up to 6000 ft (1829 m) |
| Relative humidity operating | 5% to 90% (noncondensing) |
| Relative humidity non-operating | 0% to 95% (noncondensing) |
| IEEE Standards | IEEE standard IEEE 802.1D IEEE 802.1w IEEE 802.1 IEEE 802.1Q IEEE 802.1p IEEE 802.1ad IEEE 802.3ad IEEE 802.1AB IEEE 802.3x IEEE 802.1Qbb IEEE 802.1Qaz |
| T11 Standards | INCITS T11 FC-BB-5 |
| JPSU-650W-AC-AFI | Juniper 650 W AC power supply (FRU-side to port-side airflow) |
| QFX5110-FANAFI | FANAFI fan model, back-to-front airflow |
| EX-4PST-RMK | 4 post rack mount kit |
|---|---|
| EX4650-PFL | EX4650 Premium Feature License |
| EX4650-AFL | EX4650 Advanced Feature License |
| EX-SFP-1GE-T | SFP 1000BASE-T copper transceiver module for up to 100 m transmission on Category 5 |
| EX-SFP-1GE-SX | SFP 1000BASE-SX GbE optics, 850 nm for up to 550 m transmission on multimode fiber |
| EX-SFP-1GE-LX | SFP 1000BASE-LX GbE optics, 1310 nm for 10 km transmission on single-mode fiber |
| EX-SFP-10GE-USR | SFP+ 10GbE ultra short reach optics, 850 nm for 10 m on OM1, 20 m on OM2, 100 m on OM3 multimode fiber |
| EX-SFP-10GE-SR | SFP+ 10GBASE-SR 10GbE optics, 850 nm for up to 300 m transmission on multimode fiber |
| EX-SFP-10GE-LR | SFP+ 10GBASE-LR 10GbE optics, 1310 nm for 10 km transmission on single-mode fiber |
| EX-SFP-10GE-ER | SFP+ 10GBASE-ER 10GbE optics, 1550 nm for 40 km transmission on single-mode fiber |
| EX-SFP-10GE-ZR | SFP+ 10GBASE-ZR 10GbE optics, 1550 nm for 80 km transmission on single-mode fiber |
| EX-SFP-DAC-1M | SFP+ 10GbE Direct Attach Copper (twinax copper cable), 1 m |
| EX-SFP-DAC-3M | SFP+ 10GbE Direct Attach Copper (twinax copper cable), 3 m |
| QFX-SFP-DAC-1MA | SFP+ 10GbE Direct Attach Copper (active twinax copper cable), 1 m |
| QFX-SFP-DAC-3MA | SFP+ 10GbE Direct Attach Copper (active twinax copper cable), 3 m |
| QFX-SFP-DAC-5MA | SFP+ 10GbE Direct Attach Copper (active twinax copper cable), 5 m |
| QFX-SFP-DAC-7MA | SFP+ 10GbE Direct Attach Copper (active twinax copper cable), 7 m |
| JNP-SFPP-10GE-T | SFP+ transceiver provides 100/1000/10000BASE-TX throughput up to 30m over a copper connection via an RJ-45 connector |
| JNP-25G-SR | SFP28 25GBASE-SR optics for up to 100 m transmission over serial multimode fiber-optic (MMF) OM4 fiber |
| JNP-25G-LR | SFP28 25GBASE-SR optics for up to 10 km transmission over serial single-mode fiber-optic (SMF) |
| JNP-25G-DAC-1M | 25GbE SFP28 to SFP28 copper cable, 1 m |
| JNP-25G-DAC-3M | 25GbE SFP28 to SFP28 copper cable, 3 m |
| EX-QSFP-40G-LX4 | 40GbE QSFP+ LX4 optics |
| EX-QSFP-40G-SR4 | QSFP+ 40GBASE-SR4 40GbE optics, 850 nm for up to 150 m transmission on multimode fiber |
| QFX-QSFP-40G-ESR4 | QSFP+ 40GBASE-SR4 40GbE optics, 850 nm for up to 300 m transmission on multimode fiber |
| QSFPP-40GBASE-ER4 | 40GBASE-ER4 QSFP+ pluggable transceiver |
| EX-QSFP-40G-LR4 | 40GbE QSFP+ LR4 |
| QFX-QSFP-DAC-1M | QSFP+ to QSFP+ Ethernet Direct Attach Copper (twinax copper cable), 1 m passive |
| QFX-QSFP-DAC-3M | QSFP+ to QSFP+ Ethernet Direct Attach Copper (twinax copper cable), 3 m passive |
| QFX-QSFP-DACBO-1M | QSFP+ to SFP+ 10GbE Direct Attach Breakout Copper (twinax copper cable), 1 m |
| QFX-QSFP-DACBO-3M | QSFP+ to SFP+ 10GbE Direct Attach Breakout Copper (twinax copper cable), 3 m |
| EX-QSFP-100G-SR4 | QSFP28 100GbE, SR4, 100 m |
| JNP-QSFP-100G-PSM4 | QSFP28 100GBASE-PSM4 optics for up to 500 m transmission over parallel SMF |
| JNP-QSFP-100G-CWDM | QSFP28 100GbE, CWDM4, 2 km |
| EX-QSFP-100G-LR4 | QSFP28 100GbE, LR4, 10 km |
| JNP-100G-DAC-1M | QSFP28 to QSFP28 Ethernet Direct Attach Copper (twinax copper cable) 1 m |
| JNP-100G-DAC-3M | QSFP28 to QSFP28 Ethernet Direct Attach Copper (twinax copper cable) 3 m |
| JNP-100G-4X25G-1M | QSFP28 to SFP+ 25GbE Direct Attach Breakout Copper (twinax copper cable) 1 m |
| JNP-100G-4X25G-3M | QSFP28 to SFP+ 25 GbE Direct Attach Breakout Copper (twinax copper cable) 3 m |
| EX-SFP-GE80KCW1470 | SFP, Gigabit Ethernet CWDM optics, 1470 nm for 80 km transmission on SMF |
| EX-SFP-GE80KCW1490 | SFP, Gigabit Ethernet CWDM optics, 1490 nm for 80 km transmission on SMF |
| EX-SFP-GE80KCW1530 | SFP, Gigabit Ethernet CWDM optics, 1530 nm for 80 km transmission on SMF |
| EX-SFP-GE80KCW1550 | SFP, Gigabit Ethernet CWDM optics, 1550 nm for 80 km transmission on SMF |
| EX-SFP-GE80KCW1570 | SFP, Gigabit Ethernet CWDM optics, 1570 nm for 80 km transmission on SMF |
| EX-SFP-GE80KCW1590 | SFP, Gigabit Ethernet CWDM optics, 1590 nm for 80 km transmission on SMF |
| EX-SFP-GE80KCW1610 | SFP, Gigabit Ethernet CWDM optics, 1610 nm for 80 km transmission on SMF |
The Juniper EX4650 Ethernet Switch delivers 2 Tb/s of Layer 2 and Layer 3 connectivity to networked devices such as secure routers, servers, and other switches. With 48 wire-speed 25 GbE small form-factor pluggable and pluggable plus transceiver (SFP/SFP+/SFP28) ports and 8 wire-speed 100 GbE quad SFP+ transceiver (QSFP+/QSP28) ports in a compact 1U platform, this device provides the flexibility to support mixed 1 GbE, 25 GbE and 100 GbE environments. It comes with two power cords, a 4-post rack mount kit and front-to-back airflow.
Seamless expansion of the core, distribution, campuses and access layers as business needs grow Commit and rollback functionality that ensures error-free network configurations A powerful set of scripts for on-box problem detection, reporting and resolution Throughput of up to 2 Tb/s with latency as low as 550 nanoseconds.